A Dionex UltiMate 3000 RSLCnano System was coupled online to a Q Exactive HF-X or an Orbitrap Fusion Lumos mass spectrometer (Thermo Fisher Scientific) in this study. For the final LC setup, we used nanoViper capillaries for all the connections. The pump outlet was directly connected to sample injection valve … See more Human specimen used in this study were obtained following informed consent and observing the appropriate ethics approval process of the Technical University of Munich. The study … See more Protein concentration was measured by the Bradford assay. Proteins were reduced by 10 mM DTT at 37 °C for 60 min, and alkylated by 55 mM … See more A Dionex Ultra 3000 HPLC system operating a Waters XBridge BEH130 C18 3.5 µm 2.1 × 250 mm column was used to fractionate peptides at a flow rate of 200 µl/min. Buffer A was … See more For TMT11-plex labeling, desalted peptides from HeLa, and ten pancreatic cell line protein digests were reconstituted in 0.1% FA and peptide concentration was determined by NanoDropTM 2000 (Thermo Scientific). … See more WebMicroflow SWATH ® Acquisition ... (DIA) methods1 are currently used by many proteomics labs to perform large scale quantitative experiments on thousands of proteins in complex matrices. More recently, researchers have started to use microflow LC in order to increase robustness and throughput, while still maintaining good ...
Microflow SWATH Acquisition for Quantitative Proteomics
Webproteomics High-flow (also referred to as standard flow) chromatography is the method of choice in many analytical and industrial disciplines, since it is faster, more reliable and provides better analytical separation when compared to nanoflow or microflow chromatography. WebOct 31, 2024 · Leveraging Slice-PASEF, we show, for the first time, that comprehensive profiling of single cell-level peptide amounts is possible using ultra-fast microflow chromatography and a general-purpose... breastfeeding robe
Accelerating SWATH Acquisition for Protein Quantitation Up …
WebFor applications where sample quantities are not scarce, this study shows that high proteome coverage can be obtained using a microflow LC–MS/MS system operating a 1 mm i.d. × 150 mm column, at a flow-rate of 50 μL/min … WebFor applications where sample quantities are not scarce, this study shows that high proteome coverage can be obtained using a microflow LC–MS/MS system operating a 1 … WebThe flexibility and reproducibility of the NanoLC 400 system makes it an excellent LC system for labs performing proteomics workflows, from protein expression analysis \(nanoflow\) to high throughput peptide quantitation \(microflow\). Keywords: nanoLC 400 system, quantitative proteomics, microflow Created Date: 20240101233111Z breastfeeding rockers